PCDD/PCDF Analytical Method Solutions
- U.S. EPA Method 1613
- U.S. EPA Method 8280
- U.S. EPA Method 8290
- U.S. EPA Method 23
- European Standard Method BS-EN 1948-4:201
All of our calibration kits and support solutions are designed and prepared to be used as received according to the proceedings set out in their respective methods. They are all accompanied by detailed certificate of analysis which incorporates HRMS data and RRF summaries for the calibration kits.
PCDD/PCDF RESOLUTION TESTING AND WINDOW DEFINING TEST MIXTURES
EPA Method 1613, Calibration and Verification Solution (CS3) combined with Window Defining and 2378-TCDD Resolution Testing Congeners - 500 ul in nonane
Window Defining Mixture for DB5/BP5/HP2/Rtx-5/SPB-5 - 1.2 ml in nonane
CAPILLARY COLUMN PERFORMANCE TEST MIXTURES
5CWDS - Window Defining Mixture for DB5/BP5/HP2/Rtx-5/SPB-5 - 1.2 ml in nonane
2378-TCDD Specificity Mix for DB5/BP5/HP2/Rtx-5/SPB-5 - 1.2 ml in nonane
CAPILLARY COLUMN PERFORMANCE TEST MIXTURES
2378-TCDD Specificity Mix for DB5/BP5/HP2/Rtx-5/SPB-5 - 1.2 ml in nonane
1,2,3,4-Tetrachlorodibenzo-p-dioxin 0.5 µg/ml
1,2,3,7 and 1,2,3,8-Tetrachlorodibenzo-p-dioxin mix 0.5 µg/ml
2,3,7,8-Tetrachlorodibenzo-p-dioxin 1.0 µg/ml
1,2,3,9-Tetrachlorodibenzo-p-dioxin 1.0 µg/ml
1,2,3,4-Tetrachloro[13C12]dibenzo-p-dioxin 0.5 µg/ml
2,3,7,8-Tetrachloro[13C12]dibenzo-p-dioxin 0.5 µg/ml
2378-TCDF Specificity Mix for DB/BP/HP/Rtx/SPB -225 - 1.2 ml in nonane
CAPILLARY COLUMN PERFORMANCE TEST MIXTURES
2378-TCDF Specificity Mix for DB/BP/HP/Rtx/SPB -225 - 1.2 ml in nonane
1,3,6,8-Tetrachlorodibenzofuran 1.0 µg/ml
2,3,4,7-Tetrachlorodibenzofuran 1.0 µg/ml
2,3,7,8-Tetrachlorodibenzofuran 2.0 µg/ml
2,3,7,8-Tetrachloro[13C12]dibenzofuran 0.5 µg/ml
1,2,3,9-Tetrachlorodibenzofuran 1.3 µg/ml
1,2,8,9-Tetrachlorodibenzofuran 1.2 µg/ml
Multi-Column Combined Window Defining/Resolution Mix - 1.2 ml in nonane
TDTFWD Combined Window Defining and Resolution 1.2 ml Testing Mixture for 3 Capillary Columns.
Concentrations for each compound are listed in brackets (ng/ml ± 10%)a
WINDOW DEFINING STANDARDS
5/2b
We also offer solutions to test the resolution of common HRGC columns for 2,3,7,8-TCDD and 2,3,7,8-TCDF and set retention time windows for PCDD and PCDF congener groups.
Full range Individual PCDDs & PCDFs: Native and Mass-Labelled Reference Standards can be found on pages 13-28 of the current catalogue.
Browse the full catalogue for:
- PCDD/PCDF Analytical Method Solutions
- Individual PCDDs & PCDFs: Native and Mass-Labelled
- Specialty Solution/Mixtures of PCDDs and PCDFs
- PCB Analytical Method Solutions
- Individual PCBs: Mass-Labelled
- Specialty Solution/Mixtures of PCBs
- Halogenated Flame Retardants & Related Compounds
- Perfluorinated Compounds (PFCs)
- Certified Reference Materials
Additional Products
- PAH Calibration Sets and Native Mass-Labelled Support Solutions
- Chlorinated Biphenylols (HO-PCBs), Native and Mass-Labelled Individuals, Mass Labelled Solutions & Mixtures
- Mass-Labelled Chlorinated Biphenylols Solutions/Mixtures
- Methoxy Chlorobiphenyls (MeO-PCBs), Native and Mass-Labelled Individuals and Solution/Mixtures
- Triclocarban, Native and Mass-Labelled
- Triclosan, Methyl Triclosan, Native and Mass-Labelled and Chlorinated Derivatives
- Tris(4-chlorophenyl) Methane and Methanol
- Chlorinated Naphthalenes (PCNs), Native Individuals and Solutions/Mixtures
- Chlorinated Diphenyl Ethers (PCDEs), Native and Mass-Labelled
- Native and Mass-Labelled Chlorobenzene and Chlorophenol Solution/Mixtures
- Mass-Labelled Chlorobenzenes, Chlorophenols, Chlorocatechols, and Chloroveratroles
- Native Melamine & Cyannuric Acid
- Native and Mass-Labelled Bishenol A and Native Bisphenol Analogues
- Native and Mass-Labelled Tetrachlorodibenzothiophenes
- Native and Mass Labelled Halogenated Carbazoles
Guidelines for the use and Handling of Wellington products
General Structure and Numbering System of Selected Aromatic Hydrocarbons
Number of Possible Isomers for Selcted Halogenated Aromatic Compounds
Exact Mass & Ralative Ion Abundance of Selected Chlorinated Aromatic Hydrocarbons
Molecular Ion Clusters for Cholorinated Aromatic Hydrocarbons
Exact Mass & relative Ion Abundance of Selected Brominated Aromatic Hydrocarbons
Systematic Numbering of Chlorinated Dibenzo-p-Dioxins
Systematic Numbering of Chlorinated Dibenzofurans
Systematic Numbering of Chlorinated Biphenyls
Systematic Numbering of Chlorinated Naphthalenes
Wellington Laboratories Quality Management
The people at Wellington are committed to the distribution of quality products as well as the maintenance of excellent customer service. In fact, in order to provide you with the best possible service, we now have three ISO certifications (ISO 9001:2015, ISO/IEC 17025:2017 and ISO 17034:2016) which cover all aspects of planning, production, testing, distribution, and post-distribution service.
These certifications allow us to monitor and maintain the highest level of quality and service and also allow our customers to satisfy the requirements of their own ISO certifications.
Our ISO/IEC 17025:2017 accreditation has been certified by the Canadian Association for Laboratory Accreditation Inc. (CALA) and our scope is available for review on the CALA Directory of Accredited Laboratories (http://www.cala.ca).
Similarly, our ISO 17034:2016 accreditation has been certified by ANSI National Accreditation Board (ANAB) and our certificate and scope are also available on their website (http://anab.org/).
If you require a hard copy of any of our ISO certificates, please do not hesitate to contact us at info@well-labs.com.
B. CHITTIM | C. TASHIRO | N. RIDDELL |
---|---|---|
CONTACT US
Tel: +44 (0) 151 649 4000
Email: marketing@greyhoundchrom.com
FOLLOW US
YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER