Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 
RSS

Blog posts tagged with 'capillary columns'

3M Lactic Acid Bacteria Testing | Greyhound Chromatography
3M Lactic Acid Bacteria Testing | Greyhound Chromatography
Shimadzu Autosampler Syringes | Greyhound Chromatography
New Shimadzu Autosampler Syringes - Supplied by Greyhound Chromatography
Elliot Review into the Integrity and Assurance of Food Supply Networks - Final Report | Greyhound chromatography
Elliot Review into the Integrity and Assurance of Food Supply Networks - Final Report
Girls In Science | Greyhound Chromatography
NEWS: Girls Discouraged About Careers In Science
Scientific Laboratory Consumables UK | Greyhound Chromatography

Buy Scientific Laboratory Consumables - UK Supplier

 

SGE Logo

SGE Scientific Supplies Catalogue

Higher Limits in Headspace Analysis

SGE's Diamond Headspace Syringes maintain performance up to 150 °C and continue to perform with temperature cycling resulting in an increased headspace syringe lifetime.

A series of 150 injections of samples with an incubation temperature set at 140 °C and a syringe temperature of 150 °C was realized. The whole sequence last more than 20 hours.

                                                                    

Improved Sample and Solvent Compatability

The PTFE plunger tip in Diamond Headspace Syringes enables the use of a broader range of samples and solvents compared with polymers used in plungers of other high temperature syringes, this provides greater flexibility for your headspace analyses and a longer lasting syringe.

Save Time and Improve HEadspace Analysis Workflow

Improved Workflow:

SGE's Diamond Headspace Syringes maintain performance up to 150 °C enabling you to improve your workflow by avoiding the need for transfer lines or a dedicated headspace autosampler.

Save Time

  • Diamond Headspace Syringes do not require extended equilibration unlike other headspace syringes.
  • Reduced carryover of Diamond Headspace Syringes reduces the need for flushing and washing syringes.

Ther is NO dead space on the Diamond Headspace Syringe.  The sample is completely swept from the barrel. 

 

  What's new from Chem Service  

 

CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover 

Bottle Safety Caps for mobile phase Greyhound Chromatography | AIT France HPLC Chromatography Supplies

Solvent Safety Caps

HPLC Safety Caps from Greyhound Chromatography

          AIT France Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

 

AIT HPLC Solvent Safety Caps | Greyhound Chromatography

Solvent HPLC Safety Caps from Greyhound Chromatography

          AIT Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

 CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover  

 

 

 

AIT HPLC Solvent Safety Caps | HPLC | Greyhound Chromatography

Solvent Safety Caps | HPLC Safety Caps from Greyhound Chromatography

                                                                                                           AIT Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.

Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

 CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover  

 

SGE PLOT Columns for HPLC Analysis | SGE Trahan Scientific |Greyhound Chromatography Laboratory Consumables

 

 

                  SGE Columns Catalogue Cover

SGE GC PLOT Columns - Minimal Bleed; Highly Inert; Temperature Stable

For Analysis of Gases and Volatiles

The analysis of gases and volatiles has historically been challenging for gas chromatographers. The need to maintain resolution for very volatile compounds has meant that many methods are still based on traditional packed columns. This is limiting as packed columns offer low resolution and are often dedicated to one specific analysis.

PLOT columns are ideal for separating compounds that are gases at room temperature. Trajan Scientific and Medical offers the BP BOND range of PLOT columns for analysis of fixed gases, low molecular weight hydrocarbons, volatile polar compounds and reactive analytes such as sulfur gases, amines and hydrides.

BP BOND PLOT columns are engineered to prevent the stationary phase particles from shredding downstream. Columns have been manufactured for stability at high temperatures, low bleed and high inertness levels.

BP BOND PLOT columns are available in three different phases:

  •  BP BOND Q for volatile solvents and hydrocarbons.
  • BP BOND U for trace hydrogen sulfide (H S), carbonyl sulfide (COS) and mercaptans in hydrocarbon streams
  • BP BOND Molsieve 5A for permanent gases, refinery and natural gases

Plot Column Chart

Plot Column Chart

 

 Other Products Available from Greyhound Chromatography

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

 

About the Author

Susan MAssie, Marketing Director Greyhound Chromatography Image

Susan Massie, Sales & Marketing Director, Greyhound Chromatography and Allied Chemicals Email: sue@greyhoundchrom.com

Susan Massie is the Sales & Marketing Director for Greyhound Chromatography and Allied Chemicals, affectionately known as 'Greyhound' in our scientific community. Greyhound was founded by Susan's husband Paul Massie over 40 years ago, Susan hasn't been in the business for all of that time but has been involved with Greyhound for over 17 years. Greyhound continues to grow, expanding into new markets and taking on the challenges of our ever changing environment. It's heartwarming to witness the world waking up to the fact that we are damaging our planet on a daily basis. Every action we take has a direct effect on our planet and the world we leave behind for future generations. Susan is passionate about climate change and is happy to work in an industry that can have a direct effect on reducing the impact of our actions on the environment. All of the team at Greyhound take our responsibilities very seriously, the products that we supply are used by the world's leading scientists and chemists as they endeavour to monitor and repair the environment. All is not lost, if we all take responsibility for our actions, from reducing our waste and reusing or recycling our material collateral we can make a difference. The internet is full of useful advice and guidance, Susan is proud to contribute to that wealth of knowledge whenever she can.

Greyhound prides itself on personal service which provides prompt, efficient, cost-effective, safe delivery of all products. Greyhound provides technical advice and distribution of Certified Reference Standards and Materials, Laboratory Consumables, Solvents and Reagents across all scientific disciplines. Greyhound Chromatography offers over 1 Million products from its UK warehouse. The team at Greyhound are proud to support the work of the world's leading scientists and chemists as they challenge the abuse of our planet and try to make a difference to the world we leave behind for our ancestors.

You can view Susan's Linked In Profile here https://www.linkedin.com/in/susan-massie-79ab4121/

 CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover  

Vials for PFAS Testing | Greyhound Chromatography

Q-Range™ Vials for PFAS Testing

NEW Convenience kits for Perfluoroalkyl and Polyfluoroalkyl (PFAS) Testing

Finneran RAM Vials

Because Perfluoroalkyl and Polyfluoroalkyl substances do not decompose, they can accumulate over time in the environment and the human body. There is increasing evidence that exposure to PFAS can adversely affect human health. As a result, regulatory bodies are legislating that many materials should be tested to ensure that they do not contain traces of PFAS or that the traces are below permitted legal limits.

Because PFAS are widely used in materials such as PTFE, that are commonly used in chemical analysis consumables, laboratories need new labware products to minimize background contamination from these chemicals...

9mm Screw Thread Ribbed Closure lined with 1mm Thick Polyimide/Silicone

When you are unable to use PTFE as a liner - these are the perfect alternative. The usable temperature range of this new closure is up to 130°C, and is suitable for up to 10 injections. Polyimide is amber-coloured translucent, and the white silicone rubber is a high-purity rubber composition, which reduces leaching.

Finneran RAM Vials

 

Manufactured from chemical resistant polypropylene, it is ideal for “PFAS-free” sampling, testing, storage and transportation operations. These lightweight vials are an excellent economical alternative to glass and are designed to work with most autosamplers.

Convenience Kits for PFAS Testing

The new convenience kits for PFAS testing includes 100 RAM™ threaded polypropylene vials and 100 new closures / septa, packaged in a transparent tray which fits in a bench drawer for easy access.
*Finneran R.A.M.(TM) Vials are designed specifically to work in robotic arm autosamplers and have a crimp style height with the convenience of a screw thread configuration.

Finneran Vial Sampling Kits Price list

Vial sampling kits for PFAS analysis

5390-09SFRB

30109P-1232

30509P-1232

30709P-1232

31509P-1232

9013P-12SFRB

9053P-12SFRB

9073P-12SFRB

9153P-12SFRB

Greyhound chromatography vials Image

VIALS & CLOSURES PDF

 

*Pricing and offers subject to change without notice*

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

PFAS EBook Image PFAS Environmental EBook

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image