Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 
RSS

Blog posts tagged with 'chemical supplier'

Chromatography Filtering Solutions | Greyhound Chromatography

High Quality Filtering Solutions

                                                                                Q-Fil Filters ImageQ-Fil Syringe Filters Catalogue Cover Image              Q-Fil Membrane Filters Catalogue Image

 

The main source of particle contamination in HPLC columns originate in the sample to be analysed. Therefore, the final preparation step prior to sample injection into the HPLC instrument is to remove any small particulates from the sample by filtration. Removal of the solid materials is very important as they can interfere with the compound of interest and easily clog up the column being used. This will inevitably have a detrimental effect on the performance of the column, i.e. back pressure, peak size, retention time, peak shape. Severe contamination can lead to the column being irreversibly blocked and therefore having to be replaced. Other costs can include instrument downtime, and the loss of valuable samples.

Sample Types

Samples differ in a variety of ways, they may be heavily loaded with fine or coarse particulates, dissolved in aqueous or organic solvents with varying viscosities. To facilitate the most appropriate sample preparation result, filters should be optimised to match the particular requirements of each kind of sample being injected.

Standard Samples

A matrix of 5-10mL is the most common sample volume, with low viscosity, low particle contamination and dissolved in either an organic or an aqueous solvent. Greyhound Q-Fil Regenerated Cellulose Syringe Filters are an excellent choice for such samples. Their inert housing manufactured from high density medical grade virgin polypropylene, complete with the integrated Regenerated Cellulose (RC) membrane has a high chemical resistance against the most common HPLC solvents and is very suitable for aqueous samples. Every batch is HPLC-tested for low extractables. Whilst 0.45µm is the most commonly used membrane porosity, the 0.22µm membrane provides improved purity when using capillary columns or HPLC packings with a particle size of 3µm or less

Demanding Samples

More difficult samples which contain high loads of particulates, high viscosity or unusually high volumes place additional challenges on the user when preparing samples for HPLC analysis. The particles have a tendency to block the filter, high viscosities will decrease the flow rate and high volumes increase the time required to complete the filtration process. These challenges often result in the user applying a greater degree of manual pressure to the process and potentially exceeding the maximum pressure limit of the filter with a subsequent risk of bursting the housing. As a result, the sample will be lost and a potential safety risk can arise if corrosive solvents or harmful chemicals are being filtered. To assist in overcoming these challenges, the use of Q-Fil Syringe Filters with a built in Glass Microfiber pre-filter are recommended. The pre-filter removes the larger particulates from the sample leaving only the smaller particulates to be filtered by the membrane. These filters increase the flow rate through the unit resulting in a higher volume of sample to be filtered and less pressure being required by the user.

Small Volume Samples

Smaller volume samples are often valuable and require special attention. Any loss of the analyte due to adsorption by the filter membrane or housing or a large dead volume can have a detrimental effect on the analysis. Smaller filters of 13mm and 4mm diameter decrease the dead volume to less than 25uL and 8uL respectively making them ideal for smaller volume samples.

Summary

Sample filtration is an important factor in ensuring that HPLC analysis is achieved in an efficient and cost-effective way. The extensive range of Q-Fil Syringe Filters have been developed to meet the demands of the analyst and the different sample matrices being used and without losing any of the important sample.

Quality is an Important Factor

Greyhound ensures that every batch of filters is manufactured and tested in accordance with strict ISO 9001:2000 quality procedures.

Greyhound ensures that each batch is checked prior to release for:

  •  External Dimensions
  •  Bubble Point
  • Water Flow Rate
  • UV Extractables
  • Burst Pressure and compliance - Filter Integrity.

Choosing a filter on price against quality is not cost effective in the long run.  Although higher spec filters may seem expensive it is false economy to choose cheaper filters as their fail rate is much higher, causing delays in the laboratory.

Q-Fil Syringe Filters

How to choose the right syringe filter for your application

  •    Choose the size of filter based on the volume of sample to be filtered
  •    Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the     membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass microfiber pre-filter
  •    Choose the type of membrane based on the solvent being filtered 

4mm Diameter

  • Suitable for smaller volume applications
  • Filtration area 0.1cm2
  • Maximum filtration volume <2ml
  • Maximum operating pressure 75psi (5.0 bar) at 20°C Sample volume <2ml
  • Holdup volume <8ul
Greyhound Syringe Filter 

13mm Diameter

  • Suitable for most applications
  • Filtration area 1.09cm2
  • Maximum filtration volume >10ml
  • Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <10ml
  • Holdup volume <25µl
 Greyhound Syringe Filter

30mm Diameter

  • Designed for the largest sample volumes or solvent filtration
  • Filtration area 5.39cm2
  • Maximum filtration volume <200ml
  • Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <200ml
  • Holdup volume <200µl
Greyhound Syringe Filter

25mm Diameter

  • Designed for larger sample volumes or solvent filtration Filtration area 4.08cm2
  • Maximum filtration volume >100ml
  • Maximum operating pressure 87psi (6.0 bar) at 20°C Sample volume <100ml
  • Holdup volume <100µl
 Greyhound Syringe Filter

 

Pore Sizes

Q-Fil Syringe Filters are available in 0.22µm and 0.45µm pore sizes, (other pore sizes are available on request). The 0.22µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.

Pre-filters have a glass microfiber membrane which is chemically inert and resists most solvents. Q-Fil glass microfiber pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

 Syringe Filters with Glass Microfiber Pre-Filter 

  • The glass microfiber pre-filter is mounted before the microporous filter membrane, eliminating the need for a pre-filtration step, minimising sample loss and prolonging the life of the filter membrane
  • These filters have the same high-quality filter membranes and polypropylene housings as our other Q-Fil Syringe Filters, but include a Glass Microfiber (GMF) membrane used as a pre-filter
  • Flow rates are increased and the filtrate volume is significantly greater when compared to filters without pre-filters
  • Regenerated Cellulose membrane filters with the GMF membrane incorporated as a pre-filter, are particularly useful for tissue culture media filtration, as well as for general biological sample filtration
  • These filters are ideal for general laboratory filtration of samples which contain excessive amounts of particulates
  • The glass microfiber pre-filter removes the large particulates and prevents premature clogging of the filter membrane


Greyhound Q-Fil Membrane Filters 

Q-Fil Membrane Filters set the new Quality standard for today’s analytical laboratories. Manufactured from the highest quality materials, Q-Fil Membrane Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils.

 

As a trusted name in the supply of chromatography consumables and certified reference standards, Greyhound also offers a comprehensive selection of top quality own brand products including Capillary columns HPLC columns, Syringe Filters, Consumables etc. This catalogue contains details of our range of Q-Fil Membrane Filters.  Other product catalogues are available on request. 

  These quality products are backed by the guaranteed reliability and technical support which has become synonymous with the name Greyhound. 

 

                       Q-Fil Filters Image                         Q-Fil Membrane Filters Catalogue Cover Image  

 

 Membrane Filter Comparison Chart 

 Q-Fil Membrane Filters Comparison Chart Image Q-Fil Membrane Filters Comparison Chart [2] Image

 Full details and part numbers can be found in the Q-Fil Membrane Filters Catalogue above.     

                     Q-Fil Greyhound Chromatography Membrane Filters Page

                Q-Fil Greyhound Chromatography Filter Membranes

Cat. No.

Description

41-100600

  • Stainless steel manifold
  • One 300mL stainless steel filtration unit
  • One glass collection bottle
  • One  length of hosepipe

41-100601

  • Stainless steel manifold
  • One 300mL glass filtration unit
  • One glass collection bottle
  • One length of hosepipe

41-100602

  • Stainless steel manifold
  • Three 300mL stainless steel filtration units
  • One glass collection bottle
  • One length of hosepipe

41-100603

  • Stainless steel manifold
  • Three 300mL glass filtration units
  • One glass collection bottle
  • One length of hosepipe

41-100604

  • Stainless steel manifold
  • Six 300mL stainless steel filtration units
  • One glass collection bottle
  • One length of hosepipe

41-100605

  • Stainless steel manifold
  • Six 300mL glass filtration units
  • One glass collection bottle
  • One length of hosepipe

41-100610

  • Stainless Steel Manifold, single unit

41-100611

  • Stainless Steel Manifold, three unit

41-100612

  • Stainless Steel Manifold, six unit

41-100613

  • Glass Funnel, 300mL

41-100614

  • Stainless Steel Funnel, 300mL

41-100620

  • Glass Solvent Filtration Apparatus - 300mL for 47mm dia. filters
  • Graduated glass funnel, fritted glass base with side arm, joint flask, anodized aluminium clamp, vacuum hose
41-100621
  • Glass Solvent Filtration Apparatus - 500mL for 47mm dia. filters
  • Graduated glass funnel, fritted glass base with side arm, joint flask, anodized aluminium clamp, vacuum hose
41-100622
  • Glass Funnel - 300mL
41-100623
  • Glass Funnel - 500mL
41-100624
  • Glass Solvent Collection Flask - 1000mL
41-100625
  • Glass Solvent Collection Flask - 2000mL
41-100626
  • Glass Filter Head Kit (includes 300mL Glass Funnel, Fritted Glass Base, Clamp, Silicone stopper)
41-100627
  • Glass Filter Head Kit (includes 500mL Glass Funnel, Fritted Glass Base, Clamp, Silicone stopper)
41-100628
  • Aluminium Clamp

              

 Contact Us

 Tel:           +44 (0) 151 649 4000

 Web:         www.greyhoundchrom.com

 Email:       info@greyhoundchrom.com

 

Follow Us

Facebook LogoTwitter Logo You Tube Logo Linked In Logo

You may also be interested in 

  Greyhound Chromatography ZPure Filters   Wellington Laboratories Catalogue Image   Chem Service Catalogue Image  Q-fil Syringe Filters Catalogue Cover

 Chem Service Pesticides Catalogue Image    Greyhound Chromatography Reference Standards Guide    High Purity Standards Catalogue   SGE GC Supplies Catalogue Cover

AIT Smart Safety Caps | AIT France | Greyhound Chromatography

AIT Smart HPLC Safety Caps

AIT Smart Caps

AIT Product Image    AIT Smart Caps Catalogue June 2020 Image

 

Whatever HPLC/UHPLC method is used in the laboratory, choosing the right solvents, safety handling equipment and filtration method is a very important factor to consider when working to achieve the best analytical results.  Greyhound Chromatography, experts in the field of Chromatography supply, are delighted to represent the most valued manufacturers of HPLC Products, AIT France; Solvent Safety Caps, Biosolve; Solvents and Formulations for HPLC/UHPLC/Mass Spectrometry/SFC Solvents for Gas Chromatography/ Reference Standard Solvents for Gas Chromatography and Greyhound Chromatography's Q-Fil Syringe Filters and Filter Membranes. Today’s High Tech laboratory environment demands the best results, achieved using the latest safety and production solutions.  Combined with the best consumables and equipment HPLC is a powerful tool in analysis, a must for today’s results driven, cost conscious laboratory.

AIT Smart Waste Caps reduce harmful substance emissions from waste bottles by up to 95% and are available to fit a wide range of waste bottle sizes, including drums, either directly or through the use of a suitable adapter.  They allow waste solvents from an HPLC to enter the waste bottle but prevent solvent vapours from escaping into the laboratory, by use of an activated charcoal filter cartridge. Smart Waste Caps are available to fit waste solvent containers with a wide range of threads as well as barrels of up to 200 liters in size, (custom manufacturing for other applications is available on request). 

  AIT Smart Waste Caps x 4     AIT Charcoal Filter

A wide range of Smart Waste Caps and accessories available.
Please refer to Pages 26-49 of the current catalogue
  

   

AIT Smart Healthy Caps are designed to comply with the increasing safety regulations of the modern laboratory and are manufactured from inert, chemically resistant materials, such as PTFE and polypropylene.

 

Additional Safety Information

  Basic Laboratory Safety  and Working With Solvents HSE.GOV.UK 

The use of Smart Healthy Caps can reduce harmful solvent evaporation from solvent inlet reservoirs by up to 80%, protecting health and keeping the HPLC eluent concentration accurate for several days. This is achieved by the use of a one-way check valve which allows air to enter the bottle for pressure equalization, but eliminates solvent vapour emissions.

 

  • Protect health
  • Minimise solvent evaporation
  • Maintain accurate solvent concentration
  • No external contamination of eluent

 

Smart Healthy Caps also protect solvents against external contamination and are available to fit a wide range of bottle types and sizes. They can be supplied with 1 to 5 outlet ports to accommodate multiple HPLCs. Tubing (1/ 8˝ or 1/ 16˝ od.) is securely fixed with use of the AIT universal fitting which requires no ferrule or flanging of the tube.

                                                                       AIT Smart Healthy Caps
 
A wide range of Smart Waste Caps and accessories available.
Please refer to Page 4-25 of the current catalogue
 

AIT Customised Safety Caps

AIT Safety Funnels can be installed on a can or a barrel of residual solvent.  A funnel is practical, you can add an activated charcoal cartridge if the solvent is stored in a non-ventilated room.  The activated charcoal cartridge prevents the creation of an overpressure in the can or barrel, if it is exposed to heat.  AIT Safety Funnel
AIT Laboratory Sink Sink For Biological Laboratories The sink can be used to make colorations, or for a variety of other purposes.  Outflow can be connected to a waste container . It is possible to add a safety funnel, allowing you to avoid any decanting.
 Retention Trays & Cans Avoid accidental overflows, AIT offers two different types of retention tray, with a grid or duckboard to keep the can dry.   AIT Retention Tray

 

 

MORE INFORMATION        AIT CATALOGUE DOWNLOAD

 

CONTACT US 

Tel:        +44 (0) 151 649 4000 

 Web:     www.greyhoundchrom.com 

 Email:   marketing@greyhoundchrom.com 

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

PFAS EBook Image PFAS Environmental EBook

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image   Wellington Laboratories Catalogue 2021-2023    Chem Service Catalogue Image

 

Merck - About the brands | Greyhound Chromatography
Merck - About the brands | Greyhound Chromatography
MERCK Sigma-Aldrich - About the brands | Greyhound Chromatography
MERCK Sigma-Aldrich - About the brands | Greyhound Chromatography
Bottle Safety Caps for mobile phase Greyhound Chromatography | AIT France HPLC Chromatography Supplies

Solvent Safety Caps

HPLC Safety Caps from Greyhound Chromatography

          AIT France Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

 

AIT HPLC Solvent Safety Caps | Greyhound Chromatography

Solvent HPLC Safety Caps from Greyhound Chromatography

          AIT Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

 CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover  

 

 

 

AIT HPLC Solvent Safety Caps | HPLC | Greyhound Chromatography

Solvent Safety Caps | HPLC Safety Caps from Greyhound Chromatography

                                                                                                           AIT Logo

            

AIT France presents its own Smart Caps range to suit your HPLC system at best. This range offers you two solutions: - Smart Healthy Caps-Smart Waste Caps

Smart Healthy caps are manufactured in response to modern laboratory safety regulations.

They are made of inert materials resistant to chemicals.

The use of a one-way air check valve allows for low cost safe and secure solvent extraction in your laboratory.


• No solvent evaporation
• Keep your concentration accurate for several days
• No mobile phase external contamination


AIT France offers a diversified range of activated charcoal cartridge for the emission of eluent and solvent vapours; by special charcoal impregnation, the cartridges become an excellent barrier against concentrated acids or bases.


A Smart Waste Cap forms an airtight cap, drilled with a variable number of holes to host effluents tubes outgoing from the HPLC system.

The main piece is a cartridge filled with activated charcoal attached to the cap. This filter allows the absorption of 98% of the solvent's vapours released by the solvent's can.

There are many size and configuration options available to suit your personal needs. Please refer to the catalogue for full products details.


If you have any questions regarding AIT products, please do not hesitate to contact us at sales@greyhoundchrom.com


Greyhound Chromatography is pleased to supply AIT's Smart Caps to Research and Analysis laboratories worldwide. For product information and selection assistance please contact

 

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.

Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

 CONTACT US

 Tel:        +44 (0) 151 649 4000  

 Web:     www.greyhoundchrom.com  

 Email:   info@greyhoundchrom.com

 

FOLLOW US 

 

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

 

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

 

SIGN UP HERE  

 

Greyhound Monthly Newsletter  

 

CATALOGUE DOWNLOADS  

 

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

  High Purity Standards Catalogue Cover  

 

Vials for PFAS Testing | Greyhound Chromatography

Q-Range™ Vials for PFAS Testing

NEW Convenience kits for Perfluoroalkyl and Polyfluoroalkyl (PFAS) Testing

Finneran RAM Vials

Because Perfluoroalkyl and Polyfluoroalkyl substances do not decompose, they can accumulate over time in the environment and the human body. There is increasing evidence that exposure to PFAS can adversely affect human health. As a result, regulatory bodies are legislating that many materials should be tested to ensure that they do not contain traces of PFAS or that the traces are below permitted legal limits.

Because PFAS are widely used in materials such as PTFE, that are commonly used in chemical analysis consumables, laboratories need new labware products to minimize background contamination from these chemicals...

9mm Screw Thread Ribbed Closure lined with 1mm Thick Polyimide/Silicone

When you are unable to use PTFE as a liner - these are the perfect alternative. The usable temperature range of this new closure is up to 130°C, and is suitable for up to 10 injections. Polyimide is amber-coloured translucent, and the white silicone rubber is a high-purity rubber composition, which reduces leaching.

Finneran RAM Vials

 

Manufactured from chemical resistant polypropylene, it is ideal for “PFAS-free” sampling, testing, storage and transportation operations. These lightweight vials are an excellent economical alternative to glass and are designed to work with most autosamplers.

Convenience Kits for PFAS Testing

The new convenience kits for PFAS testing includes 100 RAM™ threaded polypropylene vials and 100 new closures / septa, packaged in a transparent tray which fits in a bench drawer for easy access.
*Finneran R.A.M.(TM) Vials are designed specifically to work in robotic arm autosamplers and have a crimp style height with the convenience of a screw thread configuration.

Finneran Vial Sampling Kits Price list

Vial sampling kits for PFAS analysis

5390-09SFRB

30109P-1232

30509P-1232

30709P-1232

31509P-1232

9013P-12SFRB

9053P-12SFRB

9073P-12SFRB

9153P-12SFRB

Greyhound chromatography vials Image

VIALS & CLOSURES PDF

 

*Pricing and offers subject to change without notice*

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

PFAS EBook Image PFAS Environmental EBook

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image