Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 
RSS

Blog posts tagged with 'reference standards'

Honeywell Hydranal ™ Coulomat AK Reagent for Karl Fisher Titration | Greyhound Chromatography

Honeywell Coulometry Reagents for Karl Fischer Titration

Honeywell authorised Distributor logo Image

 HONEYWELL PRODUCT LISTING

Honeywell Hydranal ™ Coulomat AK Reagent for Karl Fisher Titration

CAS NO: NOT APPLICABLE

Anolyte for coulometric Karl Fischer titration in ketones (methanol free), preferred for cells with diaphragm

 

Honeywell Hydranal ™ Water Standards Honeywell Hydranal Coulomat Reagent for Karl Fisher Titration

 Advantages of Hydranal Coulometric Reagents

  • Easy to use
  • High accuracy for trace amounts of water
  • Stable conditions of the titration vessel
  • Broad product range
  • Long shelf life (up to five years)

 

Specifications

 

Property   Value
Suitability for KF Titration   test passed
Assay of water   60 - 110 ppm
Composition   Imidazole
Composition   2-methoxyethanol
Composition   Trichloromethane

 

Properties  

Property   Value
Boiling Point/Range     60°C (1.013 hPa)
Colour     Yellow
Density     1.200 g/cm3 (20°C)
Flashpoint     32°C
For Use With (Equipment)     KF Titration
Form     Liquid
Grade     Coulometric KF Reagents
Incompatible Materilas  
  Strong bases, Strong Oxidising Agents. Strong Acids
  Magnesium, Acid anhydrides, Zinc
Lower Explosion Limit     2.5 % (V)
Melting Point/Range     No data available
Partition Coefficient     No data available
Product Line     Hydranal ™
Solubility in Water     Partly miscable
Storage temperature     Ambient
Upper Explosion Limit     20% (V)
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     5.0 (20°C)

Safety Information      

GHS Classification

                                      

GHS05 - Corrosive        GHS08 - Health Hazard   GHS06 - Toxic    GHS02 - Flammable

 

Property Value
Precautionary Statements In case of inadequate ventilation wear respiratory protection.;Wear protective gloves/protective clothing/eye protection/face protection.;Do not breathe dust/fumes/gas/mist/vapours/spray.
Hazard Class 3
Package Group III
UN ID UN1992

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Honeywell Hydranal ™ Coulomat AF 7 Reagent for Karl Fisher Titration | Greyhound Chromatography

Honeywell Coulometry Reagents for Karl Fischer Titration

Honeywell authorised distributor logo Image

 HONEYWELL PRODUCT LIST

Honeywell Hydranal ™ Coulomat AF 7 Reagent for Karl Fisher Titration

CAS NO: NOT APPLICABLE

for coulometer AF7
Synonym(s)
Methyl Alcohol

 

Honeywell Hydranal ™ Water Standards Honeywell Coulorant Reagent AF 7 for Karl Fisher Titration

 Advantages of Hydranal Coulometric Reagents

  • Easy to use
  • High accuracy for trace amounts of water
  • Stable conditions of the titration vessel
  • Broad product range
  • Long shelf life (up to five years)

Specifications

 

Property   Value
Suitability    complying
Composition   Imidizole
Composition   sulfur dioxide

 Properties  

Property   Value
Boiling Point/Range  
  63°C (1.013 hPa)
The physical data is that of the main component
Colour     Tan
Density     0.881 g/cm3 (20°C)
Flashpoint  
  11°C
The physical data is that of the main component
For Use With (Equipment)     KF Titration
Form     Liquid
Grade     Coulometric KF Reagents
Incompatible Materials  
  Oxidising Agents  
Lower Explosion Limit  
  5.5% (V)
The physical data is that of the main component
Melting Point/Range     No data available
Partition Coefficient     No data available
Product Line     Hydranal ™
Solubility in Water     Completely miscable
Storage temperature     Ambient
Upper Explosion Limit  
  31% (V)
The physical data is that of the main component
Vapour pressure  
No data available
Viscosity     No data available
pH-Value     6.0 (20°C)

Safety Information      

GHS Classification

                                                                

      GHS08 - Health Hazard       GHS02 Flammable          GHS06 Toxic                 GHS0t Hrmful  

 

Property Value
Precautionary Statements In case of inadequate ventilation wear respiratory protection.;Do not breathe dust/fumes/gas/mist/vapours/spray.;Wear protective gloves/protective clothing/eye protection/face protection.
Hazard Class 3
Package Group II
UN ID UN1230

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Honeywell HYDRANAL™ NEXTGEN Solvent E-Fl | Greyhound Chromotography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell Authorised Distributor Logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ NEXTGEN Solvent E-Fl

Medium for volumetric two-component Karl Fischer titration (ethanol-based), Free of imidazole (free of CMR substances).

 

Honeywell Hydranal ™ Water Standards
  • Medium for volumetric two-component Karl Fischer titration (ethanol-based)
  • Free of imidazole (free of CMR substances)

Properties  

Property   Value
Colour     colourless
Density     0.895 g/cg3 
Form     Liquid
Incompatible Materials     Formation of explosive gas/air mixtures
Lower Explosion Limit     No data available
Melting Point/Range     -115°C 
Partition Coefficient     No data available
Product Line     Hydranal ™
Upper Explosion Limit     No data available
Vapor Pressure     No data available
pH - Value     5 -6

Safety Information    

GHS Classification

                           

GHS05 Corrosive       GHS02 Flammable 

Property Value
Precautionary Statements Wear protective gloves/protective clothing/eye protection/face protection.;Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Hazard Class 1
Package Group II
UN ID UN1170

Hydranal Solvent Image

 Pursuing excellence

for more than 200 years

Honeywell's story began more than 200 years ago when German chemist Johann Daniel Riedel successfully manufactured pharmaceutical products. While the world has changed greatly since then, Honeywell remains committed to providing the highest quality chemicals through innovative and cutting-edge manufacturing processes. Explore Honeywell's diverse product line to discover how Greyhound Chromatography can help your lab. 

PRODUCT LISTING

 

Honeywell Research Chemicals

Honeywell Supporting Covid 19 Research

Honeywell Pharma and Bio Pharma solutions

Honeywell Application focussed Solutions

Hydranal Karl Fisher Titration

Leading the way in innovation and safety since 1979, Hydranal™ reagents for Karl Fischer titration have been recognized as the most trusted brand in the industry.  

Honeywell Water Determination in Crude Oil  Honeywell Insulating Oil  Honeywell Nitrogen Bases  Honeywell Determinitation in Dimethyl Sulfoxide
 Honeywell Water Determinitation in Aldehydes and Ketones  Honeywell Hydranal Manual  Honeywell Karl Fisher Titration with Hydranal-Methanol Rapid  Honeywell High confidence. Accurate Results

Karl Fisher Banner Heading

Chromasolv Solvents

With more than 100 dedicated solvents and blends, Chromasolv™ solvents offer better impurity profiles and higher lot-to-lot consistency. 

 

Chromasolv High Purity Solvents  Chromasolv Head to Head comparison  Chromasolv Residual Solvents Analysis

 Fluka Analytical Standards

Be confident and advance your research with Honeywell's Fluka™ Analytical Standards.

Honeywell's standards come complete with printed COA and free expert technical support. 

Fluka Analytical Standards

STANDARDS OVERVIEW

SAMPLE CoFA

PRODUCT LIST

Honeywell Quality Assured

Contact Us

Tel:          +44 (0) 151 649 4000

Web:       www.greyhoundchrom.com

Email:    info@greyhoundchrom.com

Follow Us

Facebook LogoTwitter Logo You Tube Logo Linked In Logo

You may also be interested in 

An Overview of Honeywell's Research Chemicals 

Honeywell Powerpoint Presentation

Honeywell Reference Materials Presentation

Honeywell Analytical Reference Standards

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

HYDRANAL™ Solver (Crude) Oil Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell Authorised Distributor Logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Solver (Crude) Oil Reagent for Karl Fischer Titration

Medium for volumetric one- and two-component Karl Fischer titration in oils (chloroform-methanol-xylene-based)
Synonym(s)
1,2-Dimethylbenzene 
Honeywell Hydranal ™ Water Standards Hydranal Solver Crude Oil Reagent for Karl Fischer Titration

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

 

Assay of Water (voL KF) max 0.02 Vol %
Suitability (for KF-titration) test passed

 

Properties  

Property   Value
Boiling Point/Range     57°C (1.013hPa)
Colour     Colourless
Density     1.013g/cm3 (20°C) 
Flashpoint     6.00°C
For Use with (Equipment)     KF Titration
Form     Liquid
Incompatible Materials  
  Reducing agents, Acid anhydrides, Acid Chlorides,
Alkali metals, Oxidising agents, Acids, Strong bases
Lower Explosion Limit     No data available
Melting Point/Range     No data available
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Partly soluable
Storage temperature     Ambient
Upper Explosion Limit     No data available
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     6.0 - 7.0 (20°C)

Safety Information    

GHS Classification

                                                   

 GHS02 Flammable           GHS08 Health Hazard              GHS06 Toxic

Property Value
Precautionary Statements Do not breathe dust/fumes/gas/mist/vapours/spray.;Wear protective gloves/protective clothing/eye protection/face protection.;In case of inadequate ventilation wear respiratory protection.
Hazard Class 3
Package Group II
UN ID UN1992

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

Honeywell HYDRANAL™ Titrant 5 Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell Authorised Distributor Logo image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Titrant 5 Reagent for Karl Fischer Titration

Titrating agent for volumetric two-component Karl Fischer titration (methanol-based)
Synonym(s)
Methyl Alcohol
 
Honeywell Hydranal ™ Water Standards  Honeywell Titrant 5 Reagent for Karl Fisher Titration

Specifications

 Advantages of Hydranal two-component reagents:

  • High titration speed
  • Ideal accuracy for small amounts of water
  • High buffer capacity
  • Exact and stable titer
  • E-type reagents: reduced toxicity compared to methanol

Specifications

Titer 4.90 - 5.10 mg/ml
Suitability (for KF-titration) test passed

 

Properties  

Property   Value
Boiling Point/Range     65°C (1.013hPa)
Colour     Brown
Density     0.850 g/cm3 (20°C) 
Flashpoint     11°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric Two-Component KF Titration
Incompatible Materials  
  Reducing agents, Acid anhydrides, Acid Chlorides,
  Oxidising agents, Acids, 
Lower Explosion Limit     5.5% (V)
Melting Point/Range     -98°C
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Completely miscible
Storage temperature     Ambient
Upper Explosion Limit     31% (V)
Vapor Pressure     128 hPa (20°C)
Viscosity     No data available
pH-Value     Neutral

Safety Information    

GHS Classification

                                                   

 GHS02 Flammable           GHS08 Health Hazard              GHS06 Toxic

Property Value
Precautionary Statements Wear protective gloves/protective clothing/eye protection/face protection.;Do not breathe dust/fumes/gas/mist/vapours/spray.;In case of inadequate ventilation wear respiratory protection.
Hazard Class 3
Package Group II
UN ID UN1230

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Honeywell HYDRANAL™ Medium K Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell Authorised Distributor Logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Medium K Reagent for Karl Fischer Titration

Medium for volumetric one-component Karl Fischer titration in aldehydes and ketones (methanol free)
Synonym(s)
Methylidyne Trichloride; Trichloromethane
 
Honeywell Hydranal ™ Water Standards Honeywell Medium K Reagent for Krl Fischer Titration

Specifications

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

Assay of Water (voL KF) max 0.02 Vol.%
Suitability (for KF-titration) test passed
Composition
solvent chlorofom,
1-methoxy-2-propanol, 2,2,2-trifluoroethanol

 Properties  

Property   Value
Boiling Point/Range     58°C 
Colour     Colourless
Density     1.255 g/cm3 (20°C) 
Flashpoint     56°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric One-Component KF Titration
Incompatible Materials  
  Strong Oxidising agents, Strong Bases, Strong Acids
Lower Explosion Limit     No data available
Melting Point/Range     No data available
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Insoluble
Storage temperature     Ambient
Upper Explosion Limit     No data available
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     No data available

Safety Information    

GHS Classification

                                            

 GHS02 Flammable    GHS08 Health Hazard      GHS06 Toxic        GHS05 Corrosive

Property Value
Precautionary Statements
Do not breathe dust/fumes/gas/mist/vapours/spray.;In case of inadequate ventilation wear respiratory protection.;Wear protective gloves/protective clothing/eye protection/face protection.
Hazard Class 3
Package Group III
UN ID UN1992

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

Honeywell HYDRANAL™ Methanol Dry Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell authorised Distributor Logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Methanol Dry Reagent for Karl Fischer Titration

CAS NO: 67-56-1

Medium for volumetric one-component Karl Fischer titration
Synonym(s)
Methyl Alcohol
 
Honeywell Hydranal ™ Water Standards Honeywell Methanol Dry Reagent for Karl Fischer Titration

Specifications

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

Water (Karl Fisher) max 0.01%
Suitability (for KF-titration) test passed

 Properties  

Property   Value
Autoignition Temperature   Not auto-flammable
Boiling Point/Range     64-65°C (1.013hPa)
Colour     Colourless
Density     0.79 g/cm3 (20°C) 
Flashpoint     11°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric One-Component KF Titration
Incompatible Materials     Oxidising agents
Lower Explosion Limit     5.5% (V)
Melting Point/Range     -98°C
Partition coefficient     0.71
Product line     HYDRANAL™
Solubility in Water     Completely Miscible
Storage temperature     Ambient
Upper Explosion Limit     50% (V)
Vapor Pressure     532 hPa (50°C) 
Viscosity     0.55 mPa.s (25°C)
pH-Value     Not applicable

Safety Information    

GHS Classification

                                            

 GHS02 Flammable    GHS08 Health Hazard      GHS06 Toxic        

Property Value
Precautionary Statements
Do not breathe dust/fumes/gas/mist/vapours/spray.;In case of inadequate ventilation wear respiratory protection.;Wear protective gloves/protective clothing/eye protection/face protection.
Hazard Class 3
Package Group II
UN ID UN1230

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Honeywell HYDRANAL™ Working Medium K Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

 

Honeywell Authorised DIstributor Logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Working Medium K Reagent for Karl Fischer Titration

Medium for volumetric one-component Karl Fischer titration in aldehydes and ketones (methanol free)
Synonym(s)
Methylidyne Trichloride; Trichloromethane
 
Honeywell Hydranal ™ Water Standards Honeywell Working Medium K for Karl Fischer Titration

Specifications

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

Assay of Water (vol KF) 0.01 - 0.02%
Composition solvent chloroform, 2-chloroethanol
Suitability (for KF-titration) test passed

 Properties  

Property   Value
Boiling Point/Range     60°C (1.013 hPa)
Colour     Colourless
Density     1.350 g/cm3 (20°C) 
Flashpoint     100°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric One-Component KF Titration
Incompatible Materials  
  Strong Oxidising agents, Strong Bases, Magnesium, Lithium
Lower Explosion Limit     No data available
Melting Point/Range     No data available
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Completely Miscible
Storage temperature     Ambient
Upper Explosion Limit     No data available
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     Neutral

Safety Information    

GHS Classification

                       

    GHS08 Health Hazard            GHS06 Toxic        GHS05 Corrosive

Property Value
Precautionary Statements In case of inadequate ventilation wear respiratory protection.;Do not breathe dust/fumes/gas/mist/vapours/spray.;Wear protective gloves/protective clothing/eye protection/face protection.
Hazard Class 6.1
Package Group I
UN ID UN3382

 

 

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

Honeywell HYDRANAL™ Composite 5 Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

Honeywell Authorised Distributor logo Image

 HONEYWELL PRODUCT LISTING

HYDRANAL™ Composite 5 Reagent for Karl Fischer Titration

 
Honeywell Hydranal ™ Water Standards Honeywell Composite 5 Reagent for Karl Fischer Titration

Specifications

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

Titer (water equivalent) 4.5 - 5.5 mg/mL
Suitability (for KF-titration) test passed

Properties  

Property   Value
Boiling Point/Range     194°C (1.013 hPa)
Colour     Brown
Density     1.17 g/cm3 (25°C) 
Flashpoint     99°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric One-Component KF Titration
Incompatible Materials     Strong Oxidising agents
Lower Explosion Limit     No data available
Melting Point/Range     No data available
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Completely Miscible
Storage temperature     Ambient
Upper Explosion Limit     No data available
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     4.5 - 5.5  (20°C) 

Safety Information    

GHS Classification

                 

    GHS08 Health Hazard                   

Property Value
Precautionary Statements Do not breathe dust/fumes/gas/mist/vapours/spray.;Wear protective gloves/protective clothing/eye protection/face protection.;In case of inadequate ventilation wear respiratory protection.
Hazard Class N/A
Package Group N/A
UN ID N/A

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue  

 

Honeywell HYDRANAL™ Composite 2 Reagent for Karl Fischer Titration | Greyhound Chromatography

Honeywell Volumetry Reagents NEXTGEN Solvent

 

Honeywell Authorised Distributor Logo Image

HYDRANAL™ Composite 2 Reagent for Karl Fischer Titration

CAS NOs: (All) 111-90-0,288-32-4,7446-09-5,7553-56-2,693-98-1,68007-08-9

Honeywell Hydranal ™ Water Standards Honeywell Composite 2 Reagent for Karl Fischer Titration

Specifications

Advantages of Hydranal one-component reagents:

  • Unlimited water capacity
  • Convenient and easy to use
  • The greatest flexibility in working media selection
  • reduced toxicity compared to methanol based systems
  • Suitable for methanol-reacting compounds, e.g. ketones and aldehydes
  • Long shelf life (three years)

Improved Composition

Hydranal-Composite contains all the reactants including iodine, sulfur dioxide, and the bases imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). Adding 2-methylimidazole in addition to imidazole improves the stability and eliminates the formation of crystals which can interfere with the titrator’s performance.

Specifications

Titer 1.6 - 2.4 mg/mL
Suitability (for KF-titration) test passed

Properties  

Property   Value
Boiling Point/Range     No data available
Colour     Brown
Density     1.10 g/cm3 (20°C) 
Flashpoint     103°C
For Use with (Equipment)     KF Titration
Form     Liquid
Grade     Volumetric One-Component KF Titration
Incompatible Materials     Strong Oxidising agents
Lower Explosion Limit     No data available
Melting Point/Range     No data available
Partition coefficient     No data available
Product line     HYDRANAL™
Solubility in Water     Completely Miscible
Storage temperature     Ambient
Upper Explosion Limit     No data available
Vapor Pressure     No data available
Viscosity     No data available
pH-Value     3.0 - 4.0  (20°C) 

Safety Information    

GHS Classification

                 

    GHS08 Health Hazard                   

Property Value
Precautionary Statements Do not breathe dust/fumes/gas/mist/vapours/spray.;Wear protective gloves/protective clothing/eye protection/face protection.;In case of inadequate ventilation wear respiratory protection.
Hazard Class N/A
Package Group N/A
UN ID N/A

CONTACT US   

Tel:        +44 (0) 151 649 4000   

Web:     www.greyhoundchrom.com   

Email:   marketing@greyhoundchrom.com   

FOLLOW US   

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon    

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER   

SIGN UP HERE   

Greyhound Monthly Newsletter   

CATALOGUE DOWNLOADS   

Greyhound Q-Fil catalogue  Greyhound reference standards guide   Trajan GC Supplies catalogue 

 Greyhound Chromatography Q-Range Vials Catalogue Image     Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image

Wellington Laboratories Catalogue Image            PFAS EBook  PFAS Environmental EBook

                Wellington Perfluoroalkyl Compounds

Dandy Vice Brochure  Chem Service Catalogue